Legislation and documents
- CE marking
- The manufacturer’s declaration that the product meets all European rules that apply to it. It is neither a certificate nor a quality mark. What does CE actually mean? →
- EU declaration of conformityDoC
- The document in which the manufacturer declares, under its sole responsibility, that the product meets the listed legislation and standards. It is signed by the manufacturer, not by the lab. Technical documentation →
- Technical documentationtechnical file
- The evidence that the product meets the requirements: description, schematics, risk assessment, list of standards and test reports. The manufacturer keeps it for 10 years and presents it to the market surveillance authority on request. Technical documentation →
- Directive
- A piece of European legislation that each member state transposes into its national law. The EMC Directive 2014/30/EU is an example. Directives made simple →
- EU regulation
- A piece of European legislation that applies directly in all member states, without transposition into national law. The Cyber Resilience Act (CRA) is an example.
- Harmonised standardhEN
- A European standard whose reference has been published in the Official Journal of the EU. Meeting it gives you the presumption of conformity. Standards are voluntary, but they are the easiest way to demonstrate conformity.
- Presumption of conformity
- The assumption that a product meets the requirements of a directive because it meets the relevant harmonised standard. The manufacturer then does not have to prove conformity in another way.
- Generic and product standards
- A product standard applies to a certain type of product, for example EN 55032 for multimedia equipment or EN 55015 for lighting. If no product standard exists, the generic standards EN 61000-6-1 to 6-4 apply, depending on the environment.
- Conformity assessmentModule A, internal production control
- The procedure by which the manufacturer verifies that the product meets the requirements. For common electronics this is Module A: the manufacturer handles everything itself, without a notified body. The path to CE, step by step →
- Notified body
- An independent organisation designated by a member state to carry out conformity assessment for certain products. It is not needed for common electronics (EMC, safety, RoHS), but it is for some radio or medical products.
- Manufacturer, importer, distributor
- The manufacturer places the product on the market under its own name and is responsible for CE. The importer brings the product in from outside the EU and checks that it has CE and the documents. The distributor resells it. Anyone who sells someone else’s product under their own brand becomes its manufacturer.
- Placing on the market
- The moment a product is first made available for sale or use in the EU. From then on it must meet all applicable legislation and carry CE.
- Market surveillance
- Checks on products on the market by national market surveillance authorities (in Czechia mainly the Czech Trade Inspection Authority). They can ban sales, order a recall and impose fines.
- Test report
- The result of testing from the lab: what was measured, to which standard, in which setup and with what result. It belongs in the technical documentation.
- Pre-compliance testing
- Indicative testing during development. It reveals problems before the formal test, when a fix is already more expensive. How to prepare for EMC testing →
Directives and abbreviations
- EMCDirective 2014/30/EU
- Electromagnetic compatibility. The product must not disturb its surroundings and must withstand normal disturbances from them. What EMC tests measure →
- LVDDirective 2014/35/EU
- Electrical safety of products supplied with 50–1000 V AC or 75–1500 V DC. It protects against electric shock, fire and other hazards. Directives made simple →
- REDDirective 2014/53/EU
- Radio equipment, i.e. products with Wi-Fi, Bluetooth, LTE or another transmitter. It also covers EMC and safety requirements. Directives made simple →
- RoHSDirective 2011/65/EU
- Restriction of hazardous substances in electronics, such as lead, mercury or cadmium. Directives made simple →
- WEEEDirective 2012/19/EU
- Take-back and recycling of electronic waste. The product carries the crossed-out wheeled bin symbol and the manufacturer joins a take-back scheme. It is not part of CE.
- CRARegulation (EU) 2024/2847
- The Cyber Resilience Act. Products with software and a network connection will have to meet cybersecurity requirements. What is the CRA? →
EMC basics
- Emissions
- Disturbances that the product itself sends into its surroundings or into cables. They are measured so that the product does not interfere with radio, mobile networks or other equipment.
- Immunity
- The ability of a product to work despite disturbances from its surroundings, for example an electrostatic discharge or a nearby transmitter.
- Radiated emissions
- Disturbances that travel through the air. They are measured with an antenna in an EMC chamber, usually from 30 MHz upwards. What EMC tests measure →
- Conducted emissions
- Disturbances that the product sends into its power and data cables. They are measured from 150 kHz to 30 MHz using a LISN. What EMC tests measure →
- Class A and Class B
- Emission limit classes under EN 55032 and related standards. Class B applies to homes and offices and is stricter. Class A is for industry, and the product’s manual must warn that it may cause interference in a residential environment.
- Performance criterionA, B, C
- How the product may behave during an immunity test. A: it works normally. B: performance degrades temporarily and recovers by itself. C: the function is interrupted and restored by the operator or a restart. The standard specifies which criterion applies to which test. Performance criteria A, B, C →
- Equipment under testEUT
- The product in the setup in which it is tested, including cables, accessories and operating mode. It is worth agreeing on the setup in advance, as it affects the result.
- Residential and industrial environment
- Standards distinguish where the product is used. Emission limits are stricter in a residential environment, immunity test levels are higher in an industrial one.
Emission measurement
- DecibeldB
- A ratio unit on a logarithmic scale. +6 dB means roughly double the voltage, +20 dB ten times.
- dBµV
- Voltage in decibels relative to 1 microvolt. Used for conducted emissions: 0 dBµV = 1 µV, 60 dBµV = 1 mV.
- dBµV/m
- Electric field strength in decibels relative to 1 microvolt per metre. Used for radiated emissions. The value applies to a given measurement distance, usually 3 or 10 m.
- Limit linelimit
- The highest permitted emission level as a function of frequency. The measured spectrum must stay below it.
- Margin
- How many dB the measured value is below the limit. A reasonable margin covers differences between units in series production and measurement uncertainty.
- PeakPK
- The highest instantaneous value of the signal. Used for a quick scan of the whole band. If it is below the limit, there is no need to measure quasi-peak.
- Quasi-peakQP
- A detector that takes into account how often a disturbance repeats. It better reflects how a radio listener perceives interference. Limits are usually specified in quasi-peak.
- AverageAV
- The average signal level. For conducted emissions it is measured alongside quasi-peak and has its own, lower limit.
- Receiver bandwidthRBW
- How wide a slice of the spectrum the receiver measures at once. The standard specifies it: 9 kHz for 150 kHz–30 MHz, 120 kHz for 30 MHz–1 GHz and 1 MHz above 1 GHz.
- Measuring receiverEMI receiver, spectrum analyser
- An instrument that measures the disturbance level at individual frequencies. For formal testing it must meet the requirements of CISPR 16.
- LISNAMN, artificial mains network
- A device between the mains and the product when measuring conducted emissions. It ensures the same supply impedance in every lab and isolates disturbances coming from the mains.
- ISNimpedance stabilisation network
- The equivalent of a LISN for data and telecom cables, such as Ethernet.
- EMC chambersemi-anechoic chamber
- A shielded room with absorbing lining that blocks outside signals and suppresses reflections. The product stands on a turntable and the antenna moves up and down to find the strongest emission.
- Measuring antenna
- Different types are used for different bands, for example biconical, log-periodic or horn antennas. Measurements are taken in both horizontal and vertical polarisation.
- Near-field probe
- A small hand-held probe used to find the source of a disturbance directly on a board or cable. Useful for debugging, not used for formal testing. Failed EMC. What now? →
Immunity tests
- ESDelectrostatic discharge, EN 61000-4-2
- A discharge of static electricity from a person’s hand. Typically ±4 kV contact and ±8 kV air discharge. What EMC tests measure: ESD →
- Radiated RF fieldEN 61000-4-3
- The product is exposed to a radio-frequency field in the chamber, as if it were near a transmitter or a mobile phone. Typically 3 V/m for residential and 10 V/m for industrial use. What EMC tests measure: RF field →
- Burstelectrical fast transients, EFT, EN 61000-4-4
- Bursts of short pulses such as those caused by switching relays, contactors and motors. What EMC tests measure: burst →
- SurgeEN 61000-4-5
- A strong, slower pulse such as that caused by a lightning strike on a line or by switching in the grid. What EMC tests measure: surge →
- Conducted RF disturbancesEN 61000-4-6
- Radio-frequency disturbances injected directly into cables in the range 150 kHz to 80 MHz. What EMC tests measure: conducted RF →
- Power-frequency magnetic fieldEN 61000-4-8
- Immunity to a 50 Hz magnetic field, for example near transformers and power cables. It mainly concerns products sensitive to magnetic fields, such as Hall sensors or monitors.
- Voltage dips and short interruptionsEN 61000-4-11
- Simulation of short outages and dips in the mains voltage. What EMC tests measure: voltage dips →
- Harmonic currents and flickerEN 61000-3-2, EN 61000-3-3
- How much the product distorts the current drawn from the mains and whether it causes voltage fluctuations that show up as flickering lights. What EMC tests measure: harmonics →
Suppression and design
- Embedded system
- A computer built directly into a device that mostly does one specific job: it controls, measures or monitors. It consists of hardware, firmware, sensors, cabling and mechanics. What is an embedded system →
- Common-mode and differential-mode noiseCM, DM
- Differential-mode noise flows out and back along a pair of conductors, common-mode noise flows in the same direction on all conductors and returns through ground. Common-mode noise on cables is often the main cause of radiated emissions.
- EMI filter
- A circuit of chokes and capacitors that passes the useful signal or supply and blocks disturbances. It only works when well grounded and placed right at the connector.
- Ferriteferrite core, clip-on ferrite
- A ferrite ring on a cable that attenuates high-frequency common-mode noise. A quick fix when debugging; in a series product it is better to address the cause on the board.
- Shielding
- A conductive enclosure or cable screen that stops disturbances from spreading. The quality of the joints is what matters: a slot or a poorly terminated cable shield can make shielding useless.
- Grounding and chassis
- Connecting the reference potentials of the equipment. Short, wide, low-impedance connections matter more for EMC than the earth wire itself.
- Surge protectionTVS diode, varistor
- Components that divert a short voltage pulse away from sensitive electronics. They help with ESD and surge tests.
- Switch-mode power supplySMPS
- A power supply that switches current rapidly and thus creates disturbances at its frequency and its multiples. The most common source of conducted emissions.
- Harmonics
- Multiples of a fundamental frequency, such as a processor clock or a switch-mode supply. They show up as regular peaks in the measured spectrum.
Safety and other tests
- Electrical safety
- Protection against electric shock, fire, overheating and mechanical injury. EN 62368-1 applies to IT and multimedia equipment, EN 61010-1 to measurement and laboratory equipment.
- IP ratingEN 60529
- Two digits after the letters IP. The first indicates protection against dust and contact, the second against water. IP54, for example, means protection against dust and splashing water.
- Climatic tests
- Verification that the product withstands temperature, humidity and their changes. They are usually not required for CE, but customers or industry standards often ask for them.
Missing a term?Write to us at sales@compteq.io and we will add it. We are happy to answer a specific question about your product directly.