Emissions and immunity
Which tests apply to your product and at what severity is determined by the standard for that type of product and the environment where it will be used. An office computer is tested differently from a control unit for a factory.
Emissions: what the product emits
Radiated emissions
30 MHz – 6 GHzWhat happens: How much electromagnetic interference the product emits into its surroundings. An antenna in the EMC chamber measures the spectrum and compares it with the limit line.
Why: So that the product does not disturb broadcast radio, mobile networks, Wi-Fi or neighboring equipment.
Why products fail: Harmonics of clock frequencies, switch-mode power supplies, unfiltered cables acting as antennas, and slots in the shielding.
EN 55032, EN 55011
Conducted emissions
150 kHz – 30 MHzWhat happens: Interference the product sends into power and data cables. Measured through an artificial mains network (LISN) or, for data ports, through an ISN.
Why: The mains and cables would carry the interference to other appliances in the building.
Why products fail: A switch-mode power supply without an input filter, or with a filter that is poorly grounded or placed far from the connector.
EN 55032, EN 55011
Harmonic currents and flicker
mains up to 16 AWhat happens: How much the product distorts the current drawn from the mains and whether it causes voltage fluctuations (flickering lights).
Why: Distorted current loads the grid and affects other consumers.
Why products fail: Power supplies without power factor correction (PFC) and power loads that switch in fast cycles.
EN 61000-3-2, EN 61000-3-3
Immunity: what the product withstands
Electrostatic discharge (ESD)
criterion BWhat happens: We simulate a discharge from a human hand into metal parts, buttons, connectors and the surroundings of the product.
Level: typically ±4 kV contact, ±8 kV air
Why products fail: Processor reset or freeze, unprotected connectors and controls without protection diodes.
EN 61000-4-2
Radiated RF field
criterion AWhat happens: We expose the product in the chamber to an RF field, similar to a nearby transmitter or mobile phone.
Level: 3 V/m residential, 10 V/m industrial (chamber up to 12 V/m)
Why products fail: Sensitive analog inputs and sensors, long unshielded cables, measured values “drifting”.
EN 61000-4-3
Electrical fast transients (burst)
criterion BWhat happens: Bursts of short pulses, such as those generated when relays, contactors and motors switch.
Level: e.g. ±1 kV on residential mains, ±2 kV industrial
Why products fail: No input filtering, grounding through long wires, firmware hangs on a communication error.
EN 61000-4-4
Surge
criterion BWhat happens: A strong but slower pulse, like after a lightning strike on a line or switching in the grid. On data ports only for cables longer than 30 m.
Level: e.g. ±1 kV line to line, ±2 kV line to ground
Why products fail: No surge protection (varistor, TVS diode), or protection rated for too little energy.
EN 61000-4-5
Conducted RF disturbance
criterion AWhat happens: We inject RF disturbance directly into the cables, because below 80 MHz it enters the product mainly through them.
Level: 3 V residential, 10 V industrial, 150 kHz – 80 MHz
Why products fail: Unfiltered inputs, analog signals routed over long cables, missing ferrites.
EN 61000-4-6
Voltage dips and short interruptions
criterion B / CWhat happens: We simulate short outages and dips of the mains voltage.
Level: short outages and dips on the AC mains
Why products fail: The product does not restart properly, loses its settings or corrupts data in memory.
EN 61000-4-11
Depending on the type of product, we add further tests, such as bulk current injection (BCI) for vehicles and defense, or radio equipment tests to ETSI EN 301 489. The EMC and CE calculator shows exactly what applies to your product.
Performance criteria A, B, C
Immunity tests are not just about whether the product “survives”. The standard defines how it may behave:
- A: it works normally during the test, with no noticeable change.
- B: performance may degrade temporarily and recovers by itself once the disturbance stops.
- C: the function may be interrupted and is restored by the operator, e.g. by a restart.
You describe what “works normally” means for your product. More on this in How to prepare for EMC testing.
How to pass first time
- Think about EMC at the design stage. An input filter, connector protection and a solid ground plane on the board cost little at design time and a lot afterwards.
- Watch the cables. Where they run, how long they are and whether they are shielded. Most emission problems start with them.
- Do pre-compliance testing. You find the problem before you pay for full testing or order production.
- Keep an engineer at hand. If something fails, our engineers propose a fix directly in the schematic or the board.
The complete CE guide as a PDF
All 11 guides in one document: directives, EMC and safety testing, technical documentation, manual and rating label. For printing and for your team.
Which tests does your product need?
Based on the product type, environment and interfaces, the calculator selects the tests and shows an indicative price. Reply within 24 hours; we can usually offer testing within a week.