Why it matters
A product can pass every test and still be withdrawn from sale by the market surveillance authority because of a missing address on the label or a manual in the wrong language. The label and manual are part of the technical documentation and are assessed as strictly as the measurements.
What must be on the rating label
The label information is required by the directives under which you CE mark the product and by the safety standard for your product. For electronics, it usually comes down to this:
| Item | What and why | Rule |
|---|---|---|
| CE marking | Visible, legible and indelible, at least 5 mm high, in the prescribed proportions. The notified body number follows the marking only when the notified body is involved in production control. | Regulation 765/2008, Annex II |
| Type and serial or batch number | So that the product can be traced unambiguously. If it does not fit on the product, put it on the packaging or in the accompanying documents. | EMC Art. 7, LVD Art. 6, RED Art. 10 |
| Manufacturer and postal address | Name, registered trade name or trademark and an address where you can be contacted. For consumer products, also an e-mail address or website. | EMC Art. 7, LVD Art. 6, RED Art. 10, GPSR Art. 9 |
| Importer | If you import the product from outside the EU, add the importer’s name and address. | EMC, LVD, RED – obligations of importers |
| Electrical ratings | Rated voltage, frequency and current or power. The exact scope is set by the safety standard for your product. | e.g. EN 62368-1, EN 61010-1, EN 60598-1 |
| Protection class symbol | The double square for products with double insulation (class II). The IP rating, if you declare one. | product safety standard |
| Crossed-out wheeled bin | The product must not be disposed of with mixed waste. A bar or the date of placing on the market goes under the symbol. | WEEE 2012/19/EU, EN 50419 |
What must be in the user manual
A manual must always accompany the product, even industrial equipment. For electronics, these parts must not be missing:
- Language. The manual and safety information must be in a language easily understood by users in the country of sale.
- Intended use. What the product is for, where it may be used and what it may not be used for.
- Safety warnings. The risks and how to avoid them. Specific warnings are prescribed by the product safety standard.
- Installation and connection. How to connect, ground and mount the product correctly.
- EMC measures. If conformity depends on installation, say so: shielded cables, ferrites, cable length, grounding. A class A product must carry a warning that it may cause interference in a residential environment.
- Technical data. Power supply, power consumption, operating temperatures, IP rating, dimensions and weight.
- Maintenance and cleaning. What the user may do and what only service may do.
- Radio equipment. Frequency bands and maximum transmitted power. Include a copy of the EU declaration of conformity or a simplified declaration with a link to the full text.
- Disposal. That the product belongs to the electrical equipment take-back scheme and where to return it.
- Manufacturer contact. The same details as on the label; for consumer products, also an e-mail address or website.
Common mistakes
- Only a website on the label. A postal address where the manufacturer can be reached is mandatory. A website or e-mail is added on top.
- A CE marking drawn by eye. It has prescribed proportions and a minimum height of 5 mm. Use the official artwork.
- A manual in one language only. The manual and safety information must be in the language of each country where the product is sold.
- Missing class A warning. An industrial product without a warning about interference in residential environments will not pass a documentation review.
- The label peels off or wears away after testing. The information must be durable. Test it against the abrasion and temperatures the product will be exposed to.